  Datasheet File OCR Text:
  telaire t8000-r series wall mount co 2 and temperature transmitter with relay ? gas permeable, water resistant co 2 diffusion flter prevents particulate and water contamination of the sensor. ? locking screw secures cover and sensor to the mounting bracket for tamper resistance. ? sensors are shipped factory calibrated. ? modern enclosure ? conformal coating on 0-5000 ppm models ? low-cost ? reliable (20 years of low-cost infrared sensor manufacturing) ? available co 2 and temperature output options: voltage 0-10v or 0-5v (switch selectable) or current 4-20 ma, relay ? uip software compatible for customizations ? ce, rohs, reach and weee compliant ? lifetime calibration warranty features: ? patented, absorption infrared gas sensing engine provides high accuracy in a compact low cost package. ? patented abc logic? self-calibration system eliminates the need for manual calibration in most applications. ? lifetime co 2 calibration guarantee when using abc logic?. ? mounting plate with two-piece terminal blocks provide quick, easy wiring. the new telaire t8000-r series is a new low cost, high performing co 2 transmitter for the building controls and indoor growers markets. it works seamlessly with building automation systems, and allows you to simply and effectively control fresh air into a ventilated space to meet regulated standards, providing immediate energy savings. relay control can be used to control fresh air when no building automation system is available. the telaire 8000- r series can also be used with its built-in relay to control co 2 producing equipment to assist with plant growth. ? a mphenol advanced sensors
controlled ventilation ventilation is an important part of maintaining a comfortable, healthy, productive environment for people. improper ventilation can have a negative impact on occupant health and performance, increase the risk from litigation, and/ or waste energy. demand-controlled ventilation using co 2 sensors prevents energy losses from over-ventilation while maintaining indoor air quality. the most energy savings potential is in buildings where occupancy fuctuates during a 24-hour period. numerous organizations now require and/ or recommend co 2 -based ventilation control in different commercial hvac applications. some utility companies also offer rebates to building owners for installing co 2 sensors. wall mount sensors are used to control a specifc area such as a conference room, classroom, meeting hall, etc. the telaire 8000-r ventostat series are easy to install and have a clean, modern look that suits most indoor environments. wall mount specifcations sensing method ? non-dispersive infrared (ndir) absorption ? gold-plated optics ? patented abc logic self calibration algorithm co 2 measurement range 8100-r 0 to 2000 ppm 8200-r 0 to 5000 ppm (0 ppm = 0 v, 4 ma) co 2 accuracy 30 ppm or 3% of the reading shown, whichever is higher * active temperature accuracy /range 0-50c (32-122f) 1c from 15-30c (1.8f from 59 to 86f) power supply requirements 18-30 vac rms, 50/60 hz, or 18 to 42 vdc, polarity protected *ahrae regulation 62 states maximum indoor co 2 level of 1000 ppm power consumption typical 0.7 w at nominal voltage of 24v ac rms temperature dependence 0.2% fs per c (0.11% per f) stability <2% of fs over life of sensor (15 years) pressure dependence 0.135% of reading per mm hg *c0 2 accuracy statement excludes standard gas used for calibration that has an accuracy of 2%. in addition, there is a potential digital to analog error of up to 2%. warranty 24 months on mechanical defects calibration - lifetime warranty (abc logic on.) certifcations ce emc, rohs, reach and weee compliant signal update every 5 seconds co 2 warm-up time ? < 2 minutes (operational) ? 10 minutes (maximum accuracy) operating conditions ? 32f to 122f (0c to 50c) ? 0 to 95% rh, non-condensing storage conditions -40f to 158f (-40c to 70c) flammability classifcation ul94 5va relay normally open and normally close contacts rated load 0.50 a at 125 vac, 1a 24 vdc contact material ag + au-alloy carry current 2 a max. operating voltage 125 vac, 60 vdc max. operating current 1 a max. switching capacity 62.50 va output analog (temperature and co 2 ) ? 0 to 5 v, or 0 to 10 v switch selectable (100 ? output impedance) ? or 4 to 20 ma (rl maximum 500 ?) ? voltage and current outputs are not available simultaneously ? digital to analog error 2%
t8100 standard enclosure accessories enclosure specifcations t1508 aspiration box for duct mounting the model 1508 is designed for in-duct sampling of co 2 concentrations at fow rates greater than 400 fpm. clear cover allows for observation of the sensor. they will accommodate any of the t8000-r series, and can be used for temperature and rh when ftted. enclosure is screwed to the duct with probe inserted into air stream. air sampling probe is 1-inch (25.4mm) diameter and 8-inch (203.2mm) long. enclosure (abs plastic) has knockouts for conduit connection. note: wiring penetrations must be sealed prior to use. co 2 sensor not included. t1508 aspiration box for duct mounting t1505 splash resistant enclosure the model 1505 is designed to protect the t8000-r series in damp or wet environments as might occur in agricultural, industrial or food processing environments. this enclosure (abs plastic) is designed to protect the sensor from dripping or sprayed water. any wall mount model of the t8000-r series sensor can be installed inside the enclosure. the transparent cover allows for viewing of the sensor/display. four diffusion ports allow for entry of co 2 . knockouts are provided for conduit connection. response time of the sensor is slowed to approximately 30 minutes to measure a 90% step change in concentrations. enclosure is designed to screw directly to a wall. co 2 sensor not included. t8100-ec smaller euro enclosure relay settings switch #3 switch #4 co 2 relay threshold and hysteresis down, low down, low factory default setting 800 ppm, 100 ppm down, low up, high 1000 ppm, 100 ppm hysteresis up, high down, low 1200 ppm, 100 ppm hysteresis up, high up, high 1500 ppm, 100 ppm hysteresis note: customizable settings available via uip software t2090. sensor accuracy & field calibration co 2 abc logic self calibration t8100-r sensors employ the patented abc (automatic background calibration) logic self-calibration system. abc logic virtually eliminates the need for manual calibration in applications where the indoor co 2 level drops to outside levels during unoccupied periods (e.g. during evening hours). abc logic is a special software routine in the sensor that remembers the background readings for 14 consecutive evenings, calculates if there is a sensor drift, and then corrects for it. with abc logic enabled, the sensor will typically reach its operational accuracy after 25 hours of continuous operation at a condition that is exposed to ambient reference levels. sensors will maintain accuracy specifcations with abc logic enabled, given that it is at least three times in 14 days exposed to the reference value and this reference value is the lowest concentration to which the sensor is exposed. note: applies when used in typical indoor ambient air. consult telaire if other gases or corrosive agents are part of the application environment. co 2 calibration guarantee telaire is serious about minimizing maintenance, so each t8000-r sensor comes with a lifetime calibration guarantee.
t1552 outside air enclosure the model 1552 is a rugged weatherproof enclosure (abs plastic), designed to allow the t8100 series sensor to operate in an outdoor environment and/or where ambient temperatures are below freezing. the 1552 is ideal for monitoring outside air or co 2 as a surrogate for combustion fumes in parking garages, tunnels and loading docks. this enclosure features a temperature control circuit and internal heaters to maintain the sensor within its normal operating temperature range, even if temperatures outside the enclosure are as low as -20f (-29c). four diffusion ports allow for entry of co 2 . response time of the sensor is slowed to approximately 30 minutes to measure a 90% step change in concentrations. enclosure is designed to screw directly to a wall. co 2 sensor not included. power consumption is 24v, 1.5 amp (max), and includes the t8100 series. t1505 splash resistant enclosure and t1552 outside air enclosure ventostat uip software the ventostat uip software allows you to modify the standard settings on the t8100 series products. the software features: ? altitude adjustment for maximum accuracy performance ? analog output adjustment ? single point and span gas calibration ? turn on and off abc logic? ? graphing and logging of co 2 ? custom relay settings the software can be used by distributors to make modifcations to the t8100 prior to shipping to the customer, as well as to make adjustments in the feld. the usb cable supplies power to the ventostat, negating the need for a separate power supply. the t2090 uip software kit is supplied with a usb cable and software cd. e for euro case nothing for us case gn for no brand t8100 (0-2000 ppm) d-- r T8200 (0-5000 ppm) d-- 5p ordering information examples: t8100 - d - r = us size case 0-2000 ppm t8100-e-d-gn -5p-r = eu case, no telaire logo, 0-5000 ppm internal label note: telaire t8100-r uses the telaire 6613 co 2 sensor with patented abc logic? self-calibration. T8200-r uses the telaire 6615 co 2 sensor with dual channel self calibration. the calibration interval will depend on the installation environment. aas-920-636b-03/2014 www.amphenol-sensors.com ? 2014 amphenol corporation. all rights reserved. specifcations are subject to change without notice. other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. a mphenol advanced sensors